Effect of varying cycle time interval and aerosol pre-charge on filtration performance of polyester media

 

Dutta, Sudev ; Mukhopadhyay, Arunangshu ; Sharma, Akhil

Abstract

Present study embodies filtration characterization of two nonwoven needle-felt polyester filter materials, viz. PTFE coated and without coated media. The materials have been assessed using flyash aerosol under varying time intervals (6, 9 and 12 min) at different inlet dust densities (50, 90 and 150 g/m3). The flyash particles are charged prior to their deposition over the filter media using a three phase parallel plate box pre-charger at two different levels of pre-charge, viz. 4 kV and 8 kV along with 0 kV. Results reveal that the filtration performance for PTFE coated material is better under all conditions. However, an enhanced filtration performance in terms of particle emission and pressure drop is noted at increased pre-charge level and higher cyclic interval. It may also be noted that the level of improvement in filtration behavior for both the materials has been better at initial level of pre-charge from 0 kV to 4 kV. However, the cumulative behavior of all the factors is also found significant.


 


Keyword(s)

Aerosol pre-charge;Cycle time;Dust charge;Dust concentration;Filtration performance;Particulate emission;Polyester;Pressure drop



Full Text: PDF (downloaded 514 times)

Refbacks

  • There are currently no refbacks.